teaser Baxter Healthcare SA, the regional headquarters of Baxter Europe, Middle East and Africa (EMEA), today announced that its one billionth Viaflo bag was manufactured at its plant in Sab¡nigo, Spain.

teaser Baxter Healthcare SA, the regional headquarters of Baxter Europe, Middle East and Africa (EMEA), today announced that its one billionth Viaflo bag was manufactured at its plant in Sab¡nigo, Spain.

This European milestone follows the printed publication of a new study1 about the effects of open and closed IV infusion systems. The study adds further weight to the claim that closed systems, such as Baxters Viaflo flexible IV solution bag, can significantly reduce the risk of central venous catheter-associated bloodstream infections (CVC-BSI) compared to open systems.

Building on its well-established leadership developing innovative intravenous (IV) technologies, Baxter Healthcare SA, the regional headquarters of Baxter Europe, Middle East and Africa (EMEA), today announced that its one billionth Viaflo bag was manufactured at its plant in Sabi¡nigo, Spain.

This European milestone follows the printed publication of a new study about the effects of open and closed IV infusion systems. The study adds further weight to the claim that closed systems, such as Baxter’s Viaflo flexible IV solution bag, can significantly reduce the risk of central venous catheter-associated bloodstream infections (CVC-BSI) compared to open systems.

Baxter’s Viaflo non-PVC flexible IV solution bag offers several advantages over conventional glass container systems. In addition to being lighter in weight and virtually unbreakable, Viaflo’s closed system has also been shown to significantly reduce the risks of CVC-BSI*.

The new study1 led by Dr. Fabio Franzetti, Infectious Diseases Clinic, Sacco Hospital, Milan, Italy, involved 1173 adult patients in four intensive-care units. It investigated the effects of switching from open (glass) to closed (Viaflo) IV infusion containers on the rate and time to onset of CVC-BSI.

Article continues below this sponsored advert
Cogora InRead Image
Explore the latest advances in respiratory care at events delivered by renowned experts from CofE
Advertisement

The results revealed that the CVC-BSI* rate during the open container period was significantly higher than during the closed container period (8.2 vs. 3.5 BSI/1000 CVC days or 0.43 relative risk, p=0.01).

The probability of developing a CVC-BSI over time was also higher during the open container period (2% at days 1-3 and 5.8% at days 7-9 compared with 0.8% and 1.4% respectively for the closed system). Overall, the risk of acquiring a CVC-BSI was 61% lower during the closed container period (p=0.004).

“Switching from conventional open IV infusion containers to Viaflo flexible bag, can significantly reduce the risk of contracting central venous catheter-associated bloodstream infections. Particularly where IV therapy is administered over several days, Viaflo has been shown to be a much better option for patients, “said Dr. Franzetti.

In addition to excellent patient safety, Viaflo offers extensive drug compatibility thanks to its high stability and resistance to leaching and absorption. The triple-layer bag, made from a unique co-extruded polyolefin film, allows for minimal interaction between container and solution, resulting in a high compatibility with a wide range of drugs. Viaflo also supports IV drug admixture, which means that a high volume of drugs can be admixed to the solution in the bag, with the added advantage of a low residual volume after administration.

“The manufacture of Baxter’s one billionth Viaflo bag represents a significant achievement for a company that has been dedicated to saving and sustaining lives for more than seventy-five years,” said David Pidduck, Vice President Marketing, Medication Delivery, Baxter EMEA.

“The fact that Baxter started as the first manufacturer of commercially prepared intravenous solutions in glass containers, then evolved to PVC flexible bags, followed by non-PVC flexible bags illustrates our ongoing commitment to respond to the changing needs of our customers by pioneering the latest techniques and setting the standard for quality.”

“With more than 400 employees, the Sab¡nigo plant is devoted solely to the production of Viaflo bags mainly distributed throughout Europe. We are very proud to be a part of this milestone for Baxter,” said Santiago Castan, Sabi¡nigo Plant Manager, Baxter Spain.

Baxter’s reputation for innovation and research goes hand in hand with setting and adhering to the highest standards in patient safety. This commitment was solidified with Baxter’s signing of the Vienna Declaration on “Patient Safety in Intensive Care Medicine” at the annual conference of the European Society of Intensive Care Medicine (ESICM) on 11 October 2009.